Filtech International's 9-08 series centrifugal ventilation fan



Filtech International’s The 9-08 series high pressure fan is generally used for forging furnace and high pressure forced ventilation, and can be widely used to transport materials, transport air and non-corrosive, non-self-igniting, non-viscous substances gas.
Applications
Centrifugal fan is widely used in the cement industry, building materials industry, environmental protection industry, metallurgical industry, power industry projects such as large-scale dust collector, industrial boilers, ventilation systems, cooling,etc.
Structure
Drive, we usually divide the fan into:
In the process of choosing the fan, please select the appropriate fan according to the working conditions.
Specification
Series no. | 9-08 series | Feature selection | |||||||
Normal | anti-corrosion | wear-resisting | High temperature | anti-explosion | Remarks | ||||
Performance | Impeller diameter | 400-2000mm |
| ||||||
Rotation speed | ≤4000rpm |
| |||||||
Pressure range | 3876-10618Pa |
| |||||||
Flow range | 2473-102324㎥/h |
| |||||||
Structure | Blade type | Forward |
| ||||||
Impeller support | SWSI(Single Width, Single Inlet), DWDI(Double Width, Double Inlet), Overhung type |
| |||||||
Lubrication method | Oil bath lubrication, grease lubrication, lubrication oil station | Can be specified | |||||||
Cooling method | Air cooling, Water cooling, Oil cooling | Can be specified | |||||||
Driven mode | Direct driven, Coupling driven, Belt driven | Can be specified | |||||||
Gas composition | Gas temperature | Normal | Customer request | Customer request | ≥250℃ | Customer request |
| ||
gas characteristic | Clean gas | Corrosive gas | Particulate dust | High temperature gas | Flammable gas, explosive gas |
| |||
System configuration | Motor brand | Chinese famous brand, ABB, Siemens, WEG etc | Can be specified | ||||||
Impeller | High quality carbon steel | FRP, Stainless steel, Rubber Lining | Wear-resistant layer or wear-resistant liner, ceramic patch | High temperature high quality alloy steel | FRP, Aluminum alloy | Can be specified | |||
Air inlet cone | High quality carbon steel | FRP, Stainless steel, Rubber Lining | High quality carbon steel | High quality carbon steel | High quality carbon steel | Can be specified | |||
Casing | High quality carbon steel | FRP, Stainless steel, Rubber Lining | High quality carbon steel | High quality carbon steel | High quality carbon steel | Can be specified | |||
Air damper | High quality carbon steel | FRP, Stainless steel, Rubber Lining | High quality carbon steel | High quality carbon steel | High quality carbon steel | Can be specified | |||
Main shaft | High strength carbon steel, Alloy structural steel | Can be specified | |||||||
Bearing | ZWZ, SKF, FAG, NSK | Can be specified | |||||||
Bearing housing | Cast iron |
| |||||||
Foundation bolts | GB799-1988 |
| |||||||
Option parts | System base frame, Protective screening, Silencer, Inlet & Outlet flexible connections, Inlet & Outlet counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument. | ||||||||
Product Features
1
The fan can output higher gas pressure, and can provide more gas flow at the same time, low noise.
2
The fan blade placement angle is optimized, more wear-resistant and longer service life.
3
- The air damper can be used to flexibly adjust the pressure and flow of the fan during operation. It is also possible to select a variable frequency motor, with adjust the pressure and flow of the fan by changing the speed.
4
For the material of impeller and main shaft, we will choose high-strength carbon steel, low-alloy steel, high-temperature alloy steel, high temperature resistant high-strength alloy steel under different working conditions temperature and working speed, so that the impeller and main shaft still maintains a reliable strength at high temperature.
5
Fan systems with impeller diameters less than 1400 mm at normal temperature do not require additional bearing cooling devices, reducing users’ investment and maintenance.
6
- The impeller is annealed to eliminate the internal stress generated during welding, ensuring that the impeller does not undergo creep and cracks.
7
8
The impeller is subjected to a high standard of dynamic balance correction to ensure stable operation of the fan.
9
There are a variety of options to choose from.